Description
200KW Bidirectional AC/DC Power Energy System
Model: BIM75040-200KW | Updated: 2026-05-28
🔋 Product Overview
A high-efficiency, high-reliability bidirectional AC/DC power energy system designed for energy storage and V2G applications. It supports bidirectional energy flow between the grid and battery, enabling both charging and discharging functions in a single unit. The system features high-frequency isolation, wide voltage range compatibility, and flexible parallel expansion for diverse use cases.
✨ Core Features & Advantages
Enhanced Safety & Reliability
High-frequency isolation design ensures safety between battery and grid/load. DSP+CPLD digital control with multi-level protection against overcurrent, overvoltage, and overtemperature. Dual DSP design and support for up to 12 parallel modules for stable performance and flexible expansion.
Higher Efficiency
Eliminates line frequency transformer for higher overall efficiency (up to 95% with SiC components, 94% with Si components). The DC/DC converter uses soft-switching resonant technology, achieving up to 98% efficiency.
Intelligent & User-Friendly
Seamless grid connection/disconnection with STS module. Supports wide battery voltage range (100V~750Vdc) for passenger vehicles and 50/60Hz adaptive grid frequency.
Lower Cost & Flexible Configuration
Combines charging and inversion in one unit to reduce costs. Standard 19-inch rack installation with hot-swappable modules for flexible system design.
🌐 Typical Application Scenarios
Grid-Tied Energy Storage Systems
Commercial & Industrial Energy Storage
Electric Vehicle Charging Stations
🔌 System Topology & Working Modes
Working Modes: Charging (Grid to Battery) | Discharging (Battery to Grid/Load) | V2G | Energy Storage Backup
📋 Technical Specifications
| Section | Parameter | Specification |
|---|---|---|
| Charging Mode | ||
| AC Side Parameters | Rated Grid Voltage | 400Vac (380/400/415Vac can set) |
| Grid Voltage Range | 304Vac~485Vac | |
| Grid Voltage Frequency | 50/60±5%(50Hz/60Hz Both modes self-adaption) | |
| Voltage Systems | Three-phase four-wire (3W+PE) | |
| Input Current | ≤380A | |
| Power Factor / Current Harmonics | ≥0.99, full load / <3%, full load | |
| Battery Side Parameters | Output Voltage | 200-750VDC, rated 500VDC |
| Output Rated Current | 400A | |
| Rated Power | 200kW | |
| Power Derating | 304Vac~485Vac input, full load output | |
| Charge Efficiency | 95%max (Use SiC components), 94% (Use Si components) | |
| Voltage Regulation Accuracy | ±0.5% | |
| Current Regulation Accuracy | ±1% | |
| Ripple Factor | <1%Vo | |
| Discharging Mode | ||
| Battery Side Parameters | Rated Grid Voltage | 200-750VDC |
| Discharging Current | 400A Max | |
| AC Side Parameters (V2G/On-Grid Discharging) | Grid Voltage Range | 304Vac~485Vac |
| Grid Voltage Frequency | 50/60±5%(50Hz/60Hz Both modes self-adaption) | |
| Output Power | 200kW | |
| Efficiency | 95%max (Use SiC components), 94% (Use Si components) | |
| Protection & Other Parameters | ||
| Protection Functions | OV/OC/SC/OT Protection | Available |
| Operating Temperature | -30~65°C, 55°C above output power derating | – |
| Storage Temperature | -40~75°C | – |
| Noise | <60dB | – |
| Dimensions | 600*800*2000 mm | – |
| Weight | 260Kgs | – |
| Protection Level | IP20 (single module) | – |
| Cooling Method | Intelligent speed regulation, forced air cooling | – |
🛡️ Protection & Safety Design
- Over Voltage (OV) Protection
- Over Current (OC) Protection
- Short Circuit (SC) Protection
- Over Temperature (OT) Protection
- High-frequency isolation safety design
- Multi-level software and hardware protection
❓ Frequently Asked Questions
🔗 Related Products
🤝 Contact & Services
WhatsApp/WeChat: +86-13760212825 (Contact: COCO)
Company: Imax Power Technology Co., Ltd.
Email: info@imaxpwr.com
Services: Warranty, After-sales Support, Technical Assistance, Customized Solutions