High-efficiency energy storage, smart energy. Explore the innovation Product Center and open up a new future for green energy

125kW Bidirectional AC/DC Power Module

125kW Bidirectional AC/DC Power Module

⚡High efficiency – Up to 99% peak efficiency with 3rd-generation SiC power devices; ultra-low standby power ≤ 50 W.
🔄Bidirectional power flow – Seamless AC/DC conversion for charging and discharging; supports grid-tied, off-grid, and hybrid modes.
📊Flexible control – Constant power, constant current, and constant voltage regulation; up to 10 units in off-grid parallel operation.
🛡️Comprehensive protection – Over/under voltage, overtemperature, short‑circuit, and communication loss protection; dual‑DSP digital control for reliability.
🔧Easy maintenance – Hot‑swappable modular design, single module weight 24 kg, fault isolation without system shutdown.
📡Rich communication – RS485, CAN, and Ethernet interfaces; compatible with mainstream BMS and EMS protocols.

Rated Power: 125 kW  DC Voltage: 650–950 V      DC   Current: 0–220 A    Ingress: IP20

Description

ImaxPWR
Energy Storage Converter

BAC-1K0100-2 · 125kW

⚡ BAC-1K0100-2 Energy Storage Converter

125kW Bidirectional AC/DC Power Module

Designed for energy storage and smart grid applications, this reconfigurable non-isolated bidirectional AC/DC converter module utilizes 3rd-generation SiC power devices and coupled inductors to enable bidirectional power flow between battery and AC grid. It offers high reliability, high efficiency, strong scalability, full functionality, and easy installation & maintenance.

Efficiency ≥ 98.5%
Power 125 kW
Voltage DC 650–950 V
Ingress IP20
Module Hot-swappable

99%Peak Efficiency
125kWRated Power
10Off-grid Parallel Units
24kgModule Weight
650–950VDC Voltage Range
220ADC Current Range

⚡ Core Features & Advantages

SiC power devices · dual-DSP digital control — High efficiency · Reliable · Easy maintenance

🔋 High Efficiency SiC
  • 3rd-gen SiC power devices deliver up to 99% conversion efficiency
  • Isolated duct design for superior heat dissipation
  • Advanced software control reduces operating losses
  • Ultra-low standby power ≤ 50W
⚙️ Full Functionality Multi-mode
  • Grid-tied, off-grid, and hybrid operation; ≤ 10 units in off-grid parallel
  • Constant power, constant current, and constant voltage control
  • Communication: RS485, CAN, Ethernet
  • Dry-contact expansion and N-line switching control
  • Compatible with mainstream BMS and EMS protocols
🛡️ Safety & Reliability Dual DSP
  • Dual-DSP fully digital control for mature, reliable performance
  • Potting process resists salt spray, moisture, and mildew
  • Complies with GB / CE / UL standards
  • Comprehensive overvoltage, undervoltage, overtemperature, and short-circuit protection
🔧 Easy Maintenance Hot-swap
  • Modular design, compact size, supports hot-swapping
  • Simple wiring terminals for easy installation and removal
  • Single module weight only 24 kg for efficient maintenance
  • Single-module fault does not affect system operation, reducing downtime

🏭 Typical Applications

Flexible adaptation for energy storage · smart grid · microgrid · renewable integration

🔋
Energy Storage Systems

Battery storage, C&I storage, residential storage

🌐
Smart Grid

Frequency regulation, peak shaving, demand response

Microgrid & Renewables

PV + storage, off-grid supply, renewable integration

📋 Technical Specifications

BAC-1K0100-2 module — complete parameters

Category Parameter Value
Environmental Conditions
Operating Temperature -20°C ~ +70°C (derating above 50°C)
Storage Temperature -20°C ~ +70°C
Relative Humidity ≤ 95% RH, non-condensing
Cooling Method Forced air cooling
Protection Rating IP20
Altitude 2000m (derating above 2000m)
AC Port
Input Configuration 3-phase 5-wire
Voltage Range 323 ~ 418 Vac
Max Static Voltage (non-operating) 600 Vac
Rated Voltage 380 Vac
Rated Current 190 A
Grid Frequency 45 ~ 55 Hz (50Hz) / 55 ~ 65 Hz (60Hz)
Rated Frequency 50Hz / 60Hz
Power Factor ≥ 0.97 @20%–50% output; ≥ 0.99 @50%–100% output
THD ≤ 3% @50%–100% full load
DC Port
Voltage Range 650 ~ 950 Vdc (grid/off-grid, SPWM)
Current Range 0 ~ 220 A (adjustable limit)
Rated Current 174 A @ 720 V
Voltage Regulation Accuracy ≤ ±1%
Current Regulation Accuracy ≤ ±2% (20%–100% rated load)
Load Regulation ≤ ±0.5%
Start-up Overshoot ≤ ±3%
Grid Regulation ≤ ±0.1% (320–437 V test range)
Ripple Voltage ≤ 1% (650–1000V, 0–20MHz)
Overload Capability
0 ~ 110% Continuous (Ta ≤ 45°C)
110 ~ 120% 1 minute (Ta ≤ 45°C)
≥ 120% 200 ms
Other
Peak Efficiency ≥ 98.5% (@720Vdc, 380Vac)
Standby Power ≤ 50W (@720Vdc, 380Vac, Ta ≤ 45°C)
Noise ≤ 65dB (1m distance)
Mechanical
Dimensions (excluding handles & terminals) 640mm × 640mm × 240mm
Weight ≤ 80 kg
Note: DC voltage range corresponds to rated AC voltage 380Vac. In practice, DC voltage must exceed (2 × phase voltage peak + 30V).

🎛️ Front Panel & Interface

LED indicators · signal terminal definitions — clear and easy to use

💡 LED Indicators Front Panel
Color State Meaning
Green Steady DC dispatch operation
2s on / 1s off AC dispatch or off-grid operation
0.5s blink Standby, fault, shutdown, upgrade with CAN comm OK
Red Steady Bus overvoltage, battery overvoltage, severe imbalance, ID duplicate, DSP/CPLD failure, relay fault, efficiency anomaly, soft-start fault, sampling fault, charging fault, output short, EPO fault
0.5s blink Fan fault
Yellow Steady AC fault (over/under voltage, over/under frequency, reverse phase, phase loss, imbalance); islanding protection, output derating, battery undervoltage, overcurrent, DOD/EOD fault, bus anomaly, undervoltage, overtemperature, bridge overcurrent, auxiliary supply fault, EepromErr, calibration fault, ABU fault, output overload, internal overcurrent, grid voltage > bus voltage, HV/LV ride-through
0.5s blink DC CAN comm fault, AC parallel comm fault, SPI/SCI comm fault, charge voltage setpoint > protection value or < grid peak
DIP switch: binary 8421, right = LSB, left = MSB; down = 0, up = 1. All internal modules must match; default = 1.

🔌 Signal Terminal Definitions J1–J6 & LAN
  • J1 Grid sampling (A, B, C, N) — ABU controller grid voltage acquisition
  • J2 Grid/off-grid bus / sync signal / CAN bus (off-grid parallel)
  • J3 AC supply (L, N) — AC 220V power
  • J4 DI active input (emergency stop, external LV switch feedback)
  • J5 DO NC output / DI active input / DI passive input (charge/discharge inhibit, reserved)
  • J6 RS485 (EMS/BMS) · CAN (BMS/debug) · termination resistor
  • LAN Ethernet (EMS, alternative to RS485)
Power terminals: AC side A/B/C/N (3-phase 5-wire), DC side BAT+ / BAT-.

🔁 Electrical Topology & Working Modes

Bidirectional energy flow — grid-tied / off-grid / hybrid flexible switching

AC Side (Grid) 3-Phase 380Vac Bi BAC-1K0100-2 Bi-Directional AC/DC SiC · Dual DSP Grid Off-grid Hybrid Bi DC Side (Battery) BAT+ / BAT- 650–950Vdc Dual DSP Control Digital control · Protection Communication RS485 · CAN · Ethernet AC Power DC Power Control Comm / Feedback

SPWM modulation · Grid-tied P/Q dispatch · Off-grid V/F · DC voltage 650–950Vdc · AC rated 380Vac

🛡️ Protection & Safety

Multi-layer protection — system and personnel safety

⚡ Electrical Protection
  • AC over/under voltage protection (323–418Vac)
  • DC over/under voltage protection (650–1000Vdc)
  • Battery charge overvoltage protection (adjustable 650–1030Vdc)
  • Battery EOD protection (adjustable 650–1000Vdc)
  • AC short-circuit protection (manual reset required)
  • Internal bus over/under voltage protection
🌡️ Thermal & Environment
  • Ambient overtemperature protection (76°C)
  • Internal overtemperature auto-shutdown
  • Fan fault detection and alarm
  • Potting process: salt spray, moisture, and mildew resistance
  • Ingress protection IP20
  • Forced air cooling with isolated duct
📡 System & Communication
  • Communication interruption protection (≥30s shutdown)
  • Automatic current sharing, imbalance ≤ 5%
  • Dual-DSP redundancy for high reliability
  • CAN, SPI, SCI communication fault protection
  • Compliant with GB / CE / UL standards
  • Manual reset: via monitoring or system power cycle
⚠️ Safety Note: Installation, operation, and maintenance must be performed by trained, qualified personnel using insulated tools. Measure voltage before touching any conductor surface. Do not wear watches, bracelets, rings, or other conductive items.

🔧 Installation & Use

Mounting dimensions · cable specifications · operating environment

📐 Mounting Dimensions
  • Dimensions: 640mm × 640mm × 240mm (excluding handles & terminals)
  • Mounting holes: 6 × R3.5 × 10mm oval slots, recommended M6 bolts
  • Tolerance: >500mm ±1mm; ≤500mm ±0.5mm
  • Weight: ≤ 80 kg
  • Overvoltage category: II
  • Pollution degree: II
🔌 Cable Connections
  • Power cables: A/B/C/N 3-phase 5-wire, recommended 70mm²
  • DC cables: BAT+ / BAT-, recommended 70mm²
  • PE ground: recommended 10mm²
  • Control cables: AC220V 2×1.5mm²; CAT6 shielded Ethernet; CAN/RS485 2×1.0mm² shielded
  • Airflow: System exhaust ≥ 2 × 450 CFM
Operating conditions: Altitude < 2000m (derating above); temperature -20°C~+70°C (derating above 50°C); humidity ≤ 95% RH non-condensing; system airflow per thermal design; single module fan 450 CFM.

❓ Frequently Asked Questions

Common questions about BAC-1K0100-2

Q1 What operating modes does the BAC-1K0100-2 support?
It supports grid-tied (P/Q dispatch), off-grid (V/F), and hybrid modes. Grid-tied mode has no parallel limit; off-grid mode supports up to 10 units in parallel. Both AC dispatch and DC dispatch are available.
Q2 What is the overload capability?
At Ta ≤ 45°C: 0–110% load continuous; 110–120% load for 1 minute; ≥ 120% load for 200ms.
Q3 How do I reset the module after a fault?
Reset via monitoring system (fault clear command) or by power-cycling the module. Some faults (DC overvoltage, short circuit) require manual intervention after fault conditions are cleared.
Q4 What communication interfaces are available?
Two RS485 ports (EMS and BMS), CAN (BMS and debug), and Ethernet (LAN, EMS). J2 also provides parallel CAN bus for off-grid synchronization.
Q5 Is maintenance and replacement easy?
Yes, modular design with hot-swap support. Single module weighs only 24 kg — no need to disassemble the entire system. Just loosen the front screws, pull out the faulty module, insert a new one, and tighten. The monitoring system auto-recognizes the new module.
Q6 Can the module be used in non-battery applications?
Constant current and constant power modes are not recommended for non-battery applications, as load mismatch may trigger DC undervoltage protection. Please contact ImaxPWR support for specific use cases.

📦 Related Products

ImaxPWR energy storage and power conversion portfolio

BAC Series
30kW ~ 250kW PCS

View

BMS
Battery monitoring & protection

View

EMS
Energy management & optimization

View

ESS Integration
Custom energy storage solutions

View

🤝 Business & Service

Professional support · Custom solutions · Full lifecycle service

📞 Contact (WhatsApp / WeChat)

+86-13760212825 COCO
🏢 Company

Imax Power Technology Co., Ltd.
📧 Email

🛡️ Service Commitment

Warranty · After-sales · Technical Support · Customized Solutions

© 2026 Imax Power Technology Co., Ltd.  ·  All rights reserved  ·  imax-pwr.com

Data sourced from BAC-1K0100-2 125kW Energy Storage Converter User Manual V1.0