描述
48V Single-Phase Bidirectional AC/DC Power Module BIM Series
BIM48-3000 / BIM48-3600 / BIM48-4200 | 3000W-4200W Multi-Function Bidirectional PCS Module
Left Front View
Right Front View
Rear View
Top View
Core Features & Advantages
Bidirectional Energy Flow
Integrates charging (rectifier) and discharging (inverter) functions. Supports grid priority, off-grid priority, charging priority modes for energy storage systems.
High-Efficiency Soft Switching
Patented soft switching technology reduces switching loss. Inverter efficiency up to 93.5%, charging efficiency up to 94.5%, lower heat & longer lifespan.
Dual Communication & Parallel
Supports CAN/RS485 dual communication. Wired parallel of up to 6 units for power expansion, suitable for multi-scenario parallel applications.
UPS-Grade Bypass Switch
Built-in AC bypass, typical switching time 20ms. Seamless switch to battery power when grid fails, ensuring uninterrupted load operation.
Wide Temp & High Reliability
Operating temperature -25℃~+70℃, MTBF 250KHrs (25℃, rated input, 80% load). Industrial-grade design for harsh working conditions.
Pure Sine Wave Output
Pure sine wave output, THD 3%@resistive load, compatible with precision equipment without harmonic interference.
Function Description
- ●Standby Mode: Module stays standby, waiting for commands from the upper controller.
- ●Auto Working Mode: Supports automatic charge/discharge, bypass priority for charging, grid priority for off-grid inverter.
- Charging Status:
- When bypass is off, charging power follows upper controller command;
- When bypass is loaded, upper controller calculates remaining power for charging based on AC input current limit;
- When bypass has no load, charge battery per command power;
- Off-Grid Inverter Status:
- Without grid power, supply load via bypass and disconnect from grid;
- When grid recovers, switch to grid power automatically if voltage matches, then charge battery; inverter priority if voltage mismatches.
- Charging Status:
- ●DC Current Limit Adjustment: Only for PCS charging mode. Adjustable via upper controller, 0.1A step, 0~Max range.
- ●DC Voltage Adjustment: For charging & inverter mode. Adjustable via upper controller, 0.1Vdc step, 40V-59.5V range.
- ●Battery Over-Discharge Activation: Activates over-discharged batteries automatically. When AC power is detected, module starts up in 5s without communication, charges battery at 40V/3A until wake-up command received.
- ●Fan Control: Forced air cooling, intelligent speed adjustment based on temperature & power. Low noise & energy saving, real-time speed feedback.
- ●Output Power Limiting: Equal output power for rectifier (charging) and inverter modes.
Technical Specifications
| Module Function | Model | BIM48-3000 | BIM48-3600 | BIM48-4200 |
|---|---|---|---|---|
| Output | Inverter Power | 3000W | 3600W | 4200W |
| Charging Power | 3000W | 3600W | 4200W | |
| Inverter Output Voltage | 100Vac, 110Vac, 120Vac, 220Vac, 230Vac, 240Vac (Optional) | 220Vac, 230Vac, 240Vac (Optional) | ||
| Inverter Output Frequency | 50Hz, 60Hz (Optional) | |||
| Inverter | Overload Capacity | 100%<P≤110%: 20s 110%<P≤125%: 5s 125%<P≤150%: 2s 150%<P≤200%: 200ms |
100%<P≤150%: 2s 150%<P≤200%: 200ms |
|
| Output Waveform | Pure Sine Wave | |||
| ThdU | 3%@Resistive Load | |||
| Efficiency | Max.91.2%@120Vac, Max.93.5%@220Vac | Max.93.5%@220Vac | ||
| Parallel Operation | Up to 6 Units Wired Parallel | |||
| Rectifier (Charging) | AC Input Voltage | 90-264Vac | 176-264Vac | |
| AC Frequency Range | 47-63Hz | |||
| Max AC Input Current | 30A (System design: 15A for US, 16A for CN) | |||
| PF | 0.99@100%Load | |||
| ThdI | <5%@100%Load | |||
| Max Charging Current | 60A | 72A | 80A | |
| Charging Voltage Range | 40-59.5Vdc | |||
| Voltage Ripple | Max.700mV (0-20MHz) | |||
| Efficiency | Max.92.5%@120Vac, Max.94.5%@220Vac | Max.94.5%@220Vac | ||
| Charging Management | Upper Controller Control | |||
| AC Bypass | AC Bypass Current | Max.15A | ||
| Switching Time | Typical 20ms | |||
| Environment | Operating Temp | -25℃ ~ +70℃ (Derate above 45℃) | ||
| Storage Temp | -40℃ ~ +70℃ | |||
| Humidity | ≤95%RH, Non-Condensing | |||
| Cooling | Forced Air Cooling | |||
| Altitude | 2000m (Derate 1℃ per 200m above 2000m) | |||
| Air Pressure | 79kPa ~ 106kPa | |||
| Noise | Max.58dB (1m) | |||
Typical Applications
Residential Energy Storage
Home PV energy storage & backup power, peak load shifting & off-grid power supply for household loads.
Small Commercial & Industrial
Backup power & peak-valley arbitrage for stores, reduce electricity costs with intelligent power management.
Telecom Base Station UPS
48V battery charge/discharge control for telecom base stations, uninterrupted power supply for critical equipment.
Off-Grid PV/Wind System
Battery management for off-grid hybrid systems, stable power supply for remote areas.
UPS Uninterruptible Power
Online UPS for precision equipment & servers, seamless grid-battery switch.
Portable Power Station
Core inverter/charger for outdoor power stations & mobile power vehicles.
Installation Guide
Module Mounting
3 mounting holes on each side, fixed with 3pcs M3 screws.
Dimensions: L304mm × W165mm × H74mm, 6-φ3.5mm mounting holes, suitable for cabinet/wall mounting.
Terminal Description
Terminals: PE Ground, AC Input (L_IN/N_IN), AC Bypass Output (L_UPS/N_UPS), DC I/O (DC+/DC-), CAN/RS485, Parallel Signal, Fan Connector.

FAQ
Business & Support
Contact & Support
📞 Phone/WeChat: +86 13760212825 (COCO)
🛡️ Warranty: Standard warranty & extended warranty, repair & replacement service
🔧 Technical Support: Free consultation, design & debugging support
⚙️ Customization: Power, voltage, protocol customization available
🌐 Official Website: https://www.imax-pwr.com