Description

The IMAX1K075, V2G charging pile module has three working modes: rectification, grid-connected inverter and off-grid inverter. The working mode of the module CAN be set through CAN communication.

Product Features:

  • AC/DC bidirectional conversion with high-frequency isolation
  • Ultra-wide AC voltage range: 260Vac ~ 530Vac
  • Wide power factor adjustment range: leading 0.8 ~ lagging 0.8
  • Ultra-wide DC voltage range: 150Vdc ~ 1000Vdc
  • Wide operating temperature range: -40°C ~ 75°C
  • Automatically locks phase and connects to the grid when connected to the mains
  • Supports parallel operation of 8 modules for off-grid inversion
  • Supports AC/DC side starting
  • Supports CAN bus communication
  • Supports DC side voltage regulation, current limiting, and current sharing functions
  • Supports AC side active and reactive power control
  • Supports group control
  • Features high and low voltage ride-through capabilities
  • Equipped with battery reverse connection alarm and protection functions

Product Specification Parameters:

Environmental Technical Parameters

ItemSpecification
Operating Temperature-40°C ~ +70°C. Derating required above 55°C, -40°C ~ -20°C for sustained operation, performance specifications not guaranteed.
Storage Temperature-40°C ~ +70°C
Relative Humidity≤95%RH, non-condensing
Cooling MethodForced air cooling
AltitudeDerating required above 2000m, derating applied for every 2000m increase.
Atmospheric Pressure79kPa ~ 106kPa
Protection GradeIP20

DC Port Technical Parameters

ItemSpecification
Voltage RangeGrid-connected and parallel inversion mode: 150Vdc ~ 1000Vdc; Off-grid inversion mode: 200Vdc ~ 1000Vdc
Current Range0~73.3A (current limiting point can be set)
Rated Current22A @1000V
Maximum Output Power22kW
Stability Accuracy< ±0.5%
Load Regulation≤±1% (output load 20% ~ 100% of rated range)
Startup Overcurrent≤±0.5%
Grid Adjustment Rate≤±3%
Voltage Ripple Factor≤±0.1% (test range 320V ~ 485V), rectification mode
≤1% (300~1000V, 0~20MHz), rectification mode

AC Port Technical Parameters (Grid-connected Mode)

ItemSpecification
Voltage SystemThree-phase + PE
Voltage Range260Vac~530Vac
Maximum Static Voltage545Vac
Rated Voltage380Vac
Rated Current33A
Grid Frequency45Hz ~ 65Hz
Rated Frequency50Hz/60Hz
Maximum Output Power22kW (apparent power 24.4kVA)
Power Factor≥0.97 @20% ~ 50% output power, rated input voltage and frequency
≥0.99 @50% ~ 100% output power, rated input voltage and frequency
Power Factor Adjustment Range0.8 leading ~ 0.8 lagging
THD≤5% @50% ~ 100% full load output power
Current Control Accuracy4% Semax
Current DC Component<0.5%*rated current
Rectification-Inversion Switching Time<100ms

AC Port Technical Parameters (Off-grid Mode)

ItemSpecification
Voltage SystemThree-phase + N + PE
Rated Voltage380Vac
Rated Current33A
Rated Frequency50Hz
Output Power19.8kW (apparent power 22kVA)
Voltage THD≤3% @resistive load or full load
Stability Accuracy<5%
Output Voltage Phase<3°@balanced load
Output Voltage Imbalance<3%
Dynamic Voltage Adjustment Range±10%@20% ~ 100% R load
Output Voltage DC Component<100mV
Parallel Current Sharing<5%
Number of Parallel Units≤8
Overload Capacity110% load for 10min; 120% load for 1min; short-circuit 200ms
Supports three-phase unbalanced load, each phase can independently carry 6.6kW (apparent power 7.3kVA).
Unbalanced Load CapacityOff-grid inversion mode, can operate with RCD load. When load PF>0.9, module can load and unload normally. When load PF<=0.9, start with RCD load, allow adding and removing RCD load.

EMC Technical Parameters (Off-grid Mode)

ItemSpecification
SurgeAC port differential mode 2kV, common mode 4kV; reference standards NB/T 33001-1-2018, NB/T 33008-1-2018, IEC61000-4-5
EFTAC port 4kV, DC port 2kV, signal line 1kV; reference standards NB/T 33001-1-2018, NB/T 33008-1-2018, IEC61000-4-4
ESD4kV (contact)/8kV (air); reference standards NB/T 33001-1-2018, NB/T 33008-1-2018, IEC61000-4-2
Conducted Disturbance10Vrms, 0.15~80MHz; reference standards NB/T 33001-1-2018, NB/T 33008-1-2018, IEC61000-4-6
Radiated Disturbance10V, 80~2GHz; reference standards NB/T 33001-1-2018, NB/T 33008-1-2018, IEC61000-4-3
Power Frequency Magnetic Field30A/m; reference standards NB/T 33001-1-2018, NB/T 33008-1-2018, IEC61000-4-8
Conducted EmissionsClass B (AC side) Class A (DC side); reference standards NB/T 33001-1-2018, NB/T 33008-1-2018, IEC61000-6-4
Radiated EmissionsClass B; reference standards NB/T 33001-1-2018, NB/T 33008-1-2018, IEC61000-6-4

Other Technical Parameters

ItemSpecification
EfficiencyGrid-connected mode: ≥95.5%, @400V/800V output, rated input, 50% ~ 100% load current.
Inversion mode: ≥95.5%, @400V/800V input, rated output, 50% ~ 100% load current.
Standby Power Consumption22W (rated input voltage)
Startup Instantaneous Inrush Current≤110% of maximum output input current peak value, grid-connected mode
Current SharingIn 10% ~ 100% load, module current sharing error ≤±5% rated output current
Temperature Coefficient≤±0.01%/°C
Startup Time (via control module selection startup mode)Delay from AC power on to module output ≤8s
DC startup time can be set via monitoring module, default 0 to set value rise time 5s
Noise≤55dB(A) @ core work area (open 1m from ground 25°C)
Grounding ResistanceGrounding resistance ≤0.1Ω, withstand current ≥50A
Leakage CurrentLeakage current ≤3.5mA
Insulation ResistanceDC part, AC part to casing, and AC part to DC part insulation resistance ≥10MΩ
Insulation StrengthAC port to casing: 3535V DC voltage for 60s, no breakdown, no flashover, steady-state leakage current <1mA;
AC port to DC port: 4242V DC voltage for 60s, no breakdown, no flashover, steady-state leakage current <1mA;
DC port to casing: 3535V DC voltage for 60s, no breakdown, no flashover, steady-state leakage current <1mA;
Control signal to casing: 707V DC voltage for 60s, no breakdown, no flashover, steady-state leakage current <1mA.
ROHSROHS compliance Materials + lead free solder
Compliant with EU ROHS Directive (2011/65/EU) and its amendments (EU) 2015/863 and EU REACH Regulation (EC) No 1907/2006 and its supplementary provisions.
Dimensions84mm (height) × 300mm (width) × 395mm (depth) (note: excluding handle and socket depth)
Weight≤14kg