BIDC1500100 125kW Bi-Directional DC/DC Converter | IMAXPOWER


BIDC1500100 125kW Bi-Directional DC/DC Converter

📅 Tuesday, May 12, 2026

IMAXPOWER – Non-isolated Bi-Directional DC/DC Module for Energy Storage and Power Conversion Systems

📋 Product Specifications

Category Parameter Value Description
DC Bus Side (Port A) Rated Voltage (VANOM) 1500V
Operating Voltage Range 500V~1500V
Overvoltage Protection (VAOVP) 1570±20V (Default) 1. Threshold configurable via communication
2. Fault lock with communication reset
Undervoltage Protection (VAUVP) 470±20V (Default)
Voltage Measurement Accuracy 0.5% Rated Operating Point
Voltage Control Accuracy 0.5% Based on droop voltage when droop control enabled
Rated Current (IANOM) 100A
Battery Side (Port B) Rated Voltage (VBNOM) 1250V
Operating Voltage Range 500V~1500V
Overvoltage Protection (VBOVP) 1570±20V (Default) 1. Threshold configurable via communication
2. Fault lock with communication reset
Undervoltage Protection (VBUVP) 470±20V (Default)
Rated Current (IBNOM) 100A
Overcurrent Protection (IBOCP) 105%~120%, continuous 20s; >120% within 0.1s protection 1. Threshold configurable via communication
2. Fault lock with communication reset
Max Continuous Power 125kW Above port voltage 1250V
Current Ripple RMS ≤5%IBNOM Rated Operating Point
Voltage/Current Measurement Accuracy 0.5% / 0.4% Rated Operating Point
Current Control Accuracy 0.5% Rated Operating Point
Efficiency Max Efficiency ≥99.2% Above 1000V
CEC Efficiency ≥99% Rated Operating Point
Auxiliary Power Auxiliary Power Supply 24V±2V, <60W External power supply
Protection Features Fuse Integrated ≥100kA, ≥1500Vdc, L/R ≥3ms
Short-Circuit Protection Integrated Input/Output port short-circuit
Over-Temperature Protection Integrated Threshold configurable via communication
Communication Fault Protection Integrated Default 0.5s timeout protection, configurable
Mechanical Specifications Dimensions (W×H×L) 350×85×600mm
Weight <15kg
Cooling Method Forced Air Cooling
Protection Rating IP10
Installation Method Screw Lock
General Parameters Operating Temperature -25~45°C (ΔV≤40%) / -25~40°C (ΔV>40%) 40-55°C/45-55°C current derating
Storage Temperature -40~70°C
Humidity 5%~85%
Altitude 4000m Derating above 3000m
Noise Level ≤70dB (≤30°C: ≤75dB max)
Communication Interfaces RS-485, CAN, Ethernet Refer to protocol documentation
Safety & Compliance Withstand Voltage 3.5kV (Basic Insulation), 4.4kV (Reinforced Insulation) 60s, 50/60Hz
Standards IEC 62477, UL 1741
EMC IEC 61000-4, FCC Part15 Class A
Functional Features Operating Modes CC, CV, CP, PV
Current Response <5ms 0%~90% step
Parallel Operation Up to 40 units Current imbalance <7% in CV mode
Lifetime 20 years, MTBF 400,000h

⚠️ Note: Specifications above are based on product datasheet. Please refer to the official manual for final confirmation.

✨ Core Features & Advantages

⚡ Ultra-High Efficiency

Max efficiency up to 99.2% (above 1000V) with CEC efficiency >99%, maintaining high performance across wide power ranges.

🛡️ High Reliability Protection

Integrated short-circuit protection with ms-level fault current interruption, limiting I²t <50A²s to prevent equipment damage.

📈 High Power Density

6.34kW/L power density with forced air cooling, integrating control unit, power relays, and fuses in a compact design.

🔀 Versatile Operation Modes

Supports CC, CV, CP, and PV modes with seamless bidirectional power flow for charging and discharging applications.

🔗 Scalable Parallel Operation

Up to 40 units in parallel with current imbalance <7% in CV mode, enabling flexible power expansion for large-scale projects.

✅ Certified Safety Compliance

UL1741 and IEC 62477-1 certified, meeting EMC standards for reliable operation in complex power environments.

🌐 Typical Application Scenarios

Fuel Cell Power Generation
Solar-Storage-Charge Integrated Systems
Vehicle-to-Grid (V2G)
Storage-Charge-Test Systems
Battery Second-Life Applications

🔒 Protection & Safety Design

Multi-Level Integrated Protection

Comprehensive protection including fuses, short-circuit, over-temperature, and communication fault safeguards for system safety.

Fast Fault Interruption

ms-level fault current cutoff capability with I²t <50A²s to rapidly limit fault currents and prevent equipment damage.

Configurable Protection Parameters

Overvoltage, undervoltage, overcurrent, and overtemperature thresholds configurable via communication, with fault reset capability.

Stringent Safety Certifications

UL1741 and IEC 62477-1 certified, meeting IEC 61000-4 and FCC Part15 EMC standards for complex power environments.

❓ Frequently Asked Questions

Q1: How many units can the module support in parallel operation?

Supports up to 40 modules in parallel with current imbalance <7% in constant voltage mode, enabling flexible power expansion for large-scale energy storage or power conversion projects.

Q2: What is the maximum efficiency of the module?

The module achieves a maximum efficiency of ≥99.2% at voltages above 1000V, with CEC efficiency ≥99%, maintaining high efficiency across wide power ranges.

Q3: Can overvoltage/undervoltage protection thresholds be configured?

Yes. Overvoltage, undervoltage, overcurrent, and overtemperature thresholds can be set and saved via communication. Fault-locked states can also be reset via communication commands to meet different system protection requirements.

Q4: Does the module require external power supply?

Yes. The module requires an external 24V±2V auxiliary power supply with power <60W to power the control unit and communication interfaces.

📦 Related Products

*Example products. Visit our official website for full product lineup.

📞 Contact & Services

WhatsApp/WeChat: +86-13760212825 (Contact: COCO)

Services: Warranty, After-sales Support, Technical Assistance, Customized Solutions

Product Center |
Case Studies |
Solutions |
Contact Us


Get In Touch​

We will reply you in 24 hours​

Get In Touch

We will reply you in 24 hours,

We respect your confidentiality and all information are protected.