📩 Contact via Email

✉️ Send email directly

💬 WhatsApp

WhatsApp QR Code

Scan to add, consult anytime

📱 Open chat directly

💖 WeChat

WeChat QR Code

Scan to add WeChat, one-on-one communication

High-efficiency energy storage, smart energy. Explore the innovation Product Center and open up a new future for green energy

V2G Bidirectional AC/DC Power Module — Core for Vehicle-to-Grid Interaction 20kW / 15kW · 200–750Vdc BAC75040II / BAC300100II /BAC80040

V2G Bidirectional AC/DC Power Module — Core for Vehicle-to-Grid Interaction 20kW / 15kW · 200–750Vdc BAC75040II / BAC300100II /BAC80040

BAC Series High-Frequency Isolation · Bidirectional Power Flow

Three-level technology & soft-switching resonant topology · Up to 98% efficiency · Dual-DSP digital control · CAN/RS485 communication · Ideal for energy storage, V2G, battery formation & DC aging

Widely used in energy storage systems, battery formation & grading, emergency power supplies, and DC aging test systems. The preferred choice for industries requiring bidirectional energy flow.

Description



⚡ IMAXPWR · Bidirectional Isolated AC/DC Module

BAC Series
High-Frequency Isolation · Bidirectional Power Flow

Three-level technology & soft-switching resonant topology · Up to 98% efficiency ·
Dual-DSP digital control · CAN/RS485 · Ideal for energy storage, V2G, battery formation & DC aging



98%
Peak Efficiency
AC/DC + DC/DC stages

12
Parallel Units
Scalable power expansion

100–750V
Wide Voltage Range
Covers passenger EVs & more

20kW
Rated Power
Per module (BAC80040/75040II)



📋 Module Overview

🔧 Technical Architecture

The bidirectional isolated AC/DC module employs three-level technology for seamless AC/DC conversion.
The DC/DC stage uses high-frequency isolated bidirectional conversion with soft-switching resonant technology,
enabling efficient bidirectional energy flow with automatic charge/discharge switching.
Dual-DSP architecture ensures stable performance, supports module paralleling (up to 12 units),
and features CAN & RS485 communication for easy integration with third-party systems.

🎯 Application Positioning

Widely used in energy storage systems, battery formation & grading, emergency power supplies,
and DC aging test systems. The preferred choice for industries requiring bidirectional energy flow.



⭐ Product Advantages

🛡️ Safer & More Reliable

  • ▸ Full high-frequency isolation ensures battery-grid/load safety
  • ▸ DSP+CPLD full digital control with multi-level hardware/software protection
  • ▸ Reliable parallel operation, up to 12 modules
  • ▸ Strong grid adaptability

⚡ Higher Efficiency

  • ▸ High-frequency isolation eliminates bulky transformers, efficiency >95%
  • ▸ AC/DC three-level technology, peak efficiency 98%
  • ▸ DC/DC soft-switching resonant, peak efficiency 98%

🧠 Smart & User-Friendly

  • ▸ Grid-tied and off-grid modes (V2G, V2L)
  • ▸ Wide battery voltage: 100V–750Vdc
  • ▸ Wide grid range & 50/60Hz auto-adaptation

🔧 Flexible Configuration

  • ▸ 19-inch standard rack mount, compact design
  • ▸ Hot-swappable modules for flexible configuration
  • ▸ Ideal for energy storage, formation, and aging feedback systems



📊 Technical Specifications

BAC Series Module Technical Parameters

Model BAC80040 BAC75040II BAC300100II
🔋 Charging Section
Rated Grid Voltage 400Vac (380/400/415Vac configurable)
Grid Voltage Range 304Vac–485Vac
Grid Frequency 50/60±5% (auto-adaptive)
Configuration 3-phase 4-wire (3W+PE)
Input Current ≤38A
⚡ AC Side Parameters
Power Factor ≥0.99, full load
Current THD <3%, full load
Output Voltage 150–800VDC 200–750VDC 100–300VDC
Rated Voltage 500VDC 500VDC 150VDC
Output Current 40A MAX 40A MAX 100A MAX
Rated Power 20kW 20kW 15kW
Power Derating Linear at 304–323Vac input; full at 323–485Vac
Charging Efficiency 95% Max (SiC), 94% (Si)
🔋 Battery Side (Charging)
Voltage Regulation ±0.5%
Current Accuracy ±1%
Ripple Coefficient <1% Vo
🔋 Discharging Section
Battery Voltage Range 150–800VDC 200–750VDC 100–300VDC
Discharge Current 40A Max 40A Max 100A Max
🚗 V2G (Grid-Tied Discharging)
Grid Voltage Range 304Vac–485Vac
Grid Frequency 50/60±5% (auto-adaptive)
Output Power 20KVA Max 20KVA Max 15KVA Max
Derating Linear at 304–323Vac; full at 323–485Vac
Efficiency 95% Max (SiC), 94% (Si)
🏠 V2L (Bidirectional Discharging)
Load Voltage 400Vac (380/400/415Vac configurable)
Load Frequency 50/60Hz±1% 50/60Hz±1% 50/60Hz±1%
Voltage Drop <3% <3% <3%
Output Power 20KVA 3-phase
6.6KVA 1-phase
20KVA 3-phase
6.6KVA 1-phase
15KVA 3-phase
5KVA 1-phase
🛡️ Protection & Environment
Overvoltage Protection Yes
Overcurrent Protection Yes
Short-Circuit Protection Yes
Overtemperature Protection Yes
Operating Temp. -30~65 ℃ (derating above 55℃)
Storage Temp. -40~75 ℃
Noise <60dB
Dimensions (W×D×H) 442×575×86mm
Weight 19Kg 19Kg 15Kg
Ingress Protection IP20 (single module)
Cooling Intelligent speed control, forced air
Communication CAN 2.0B / RS485
Safety Standards GB/T 34120-2017 · GB/T 34133-2017
NB/T 33001-2018 · NB/T 33008-2018
EMC Class A per NB/T 33001-2018 & NB/T 33008-2018



🌍 Application Areas

🚗 V2G (Vehicle-to-Grid)

With the growing EV fleet (forecast 80 million by 2030), EVs serve as flexible loads and distributed energy resources.
V2G bidirectional DC charging stations (up to 250kW) enable bidirectional energy flow between EVs and the grid:
charge during off-peak, discharge during peak for price arbitrage, enhance load flexibility,
reduce grid infrastructure investment, and boost renewable integration.

♻️ Battery Second-Life

Modular PCS ideal for retired EV battery second-life applications, covering 15kW–250kW for C&I parks.
Flexible embedded PCS with isolated bidirectional AC/DC for enhanced safety, efficiency, and compact size.
Grid-tied/off-grid integrated design supports microgrids (islands, remote villages). Wide voltage range perfectly suits
retired automotive battery repurposing. Configurable as mobile energy storage for critical temporary power.

🔋 Battery Formation & Grading

Two revolutionary advancements: (1) Energy feedback replaces resistive load banks, saving energy and reducing heat;
(2) High-frequency isolation replaces line-frequency transformers, improving efficiency, lowering cost, and reducing footprint.
The bidirectional high-frequency isolated power supply for formation & grading connects battery packs directly to modules,
eliminating bulky transformers with higher efficiency and smaller size.

⚙️ DC Aging Test Systems

During production aging of DC power supplies (charging piles, telecom power, etc.), traditional resistive or electronic loads waste enormous energy.
By integrating the AC/DC module into the aging process, energy is fed back to the grid, saving at least 95% of electricity costs.



⚡ Electrical Topology & Operating Modes


AC Grid

AC/DC Three-Level · Bidirectional

DC/DC High-Freq Isolation · Resonant

Battery

↔ Bidirectional ↔ Bidirectional

Grid-Tied / Off-Grid V2G / V2L

Charging (Grid → Battery)
Discharging (Battery → Grid/Load)
High-Frequency Isolation

Operating Modes: Grid-Tied Charging (AC→DC) ·
Grid-Tied Inverting (DC→AC) ·
Off-Grid Inverting (DC→AC, seamless transition)

Source: IMAXPWR Official Technical Specifications



🛡️ Protection & Safety

10+
Multi-Layer Protection
Overvoltage, overcurrent, short-circuit, overtemperature, reverse polarity

μs
Hardware Response
Hardware overcurrent protection < 10μs

≥100k
MTBF
Mean time between failures ≥ 100,000 hours

IP20
Ingress Protection
Single module IP20, suitable for industrial environments

Full high-frequency isolation · DSP+CPLD digital control · Multi-level hardware/software protection



🔧 Module Maintenance & Replacement

📋 Routine Maintenance

  • 1. Check operating conditions: temperature, humidity, I/O voltage, frequency, LED indicators, alarms
  • 2. Check for abnormal noise; inspect fans and bidirectional modules
  • 3. Inspect AC/DC terminals for tightness, cables for integrity; guard against rodents
  • 4. Verify system monitoring panel: all units normal, no faults or alarms
  • 5. Clean dust from equipment as needed
  • 6. Record ambient temperature and humidity
  • 7. Verify module parameter configuration

🔄 Replacement Procedure

  1. Remove the faulty module (caution: high internal temperature or residual voltage)
  2. Confirm the new module is intact
  3. Shut down all running modules in the system
  4. Open AC/DC breakers of the faulty module; loosen fixing screws
  5. Grasp the handle and slowly pull out; when two-thirds out, have two people lift it out
  6. Align the new module with the slot and push it in slowly until firmly seated
  7. Secure with two fixing screws
  8. Close AC/DC breakers
  9. Verify the monitoring panel recognizes the new module, communication is normal, and current sharing is balanced



❓ Frequently Asked Questions

Q What communication protocols does the BAC series support?
Supports CAN 2.0B and RS485 interfaces for easy integration with third-party equipment.

Q How many modules can be paralleled?
Supports reliable parallel operation with up to 12 modules for power expansion.

Q What is the operating temperature range?
Operating: -30~65 ℃ (derating above 55℃). Storage: -40~75 ℃.

Q Does the module support hot-swapping?
Yes, hot-swappable design for flexible system configuration and maintenance.

Q What standards does the product comply with?
Meets both charging pile and energy storage converter standards: GB/T 34120-2017, GB/T 34133-2017, NB/T 33001-2018, NB/T 33008-2018.



🔗 Related Products

▶ BIM Series 1200-2400W
Bidirectional inverter module with integrated MPPT · pure sine wave · high-efficiency soft-switching · CAN/RS485
▶ BIM30060 / BIM300100
15kW bidirectional AC/DC module · 40–300Vdc · three-level + soft-switching · dual-DSP · up to 12 parallel
▶ BIM300120
15kW bidirectional high-frequency isolated AC-DC · 40–300Vdc / 120A · grid-tied/off-grid · 32 parallel
▶ 20kW Bi-directional AC/DC PCS
DC200–1000V · three-level topology · >98.5% efficiency · <10ms switching · multi-machine parallel to 2MW
▶ IBDC30060
15kW bidirectional high-frequency isolated DC-DC · 40–300Vdc / 350–850Vdc · 32 parallel · CAN/RS485
▶ BIML75040 / BIML300100
180–250kW modular PCS · V2G high-frequency isolation · STS seamless grid/off-grid switching · 100–750Vdc

View all products →



🤝 Business & Services

ImaxPWR (Imax Power Technology Co., Ltd.) is a
national high-tech enterprise specializing in new energy.
As an original equipment manufacturer, we provide integrated energy storage products and system solutions,
covering bidirectional PCS, DC/DC, MPPT, hybrid inverters, AC integrated cabinets,
and microgrid systems for islands, mines, oilfields, and regions across Asia, Africa, Latin America, Europe, and Australia.
We are a national high-tech enterprise integrating R&D, production, and sales,
with extensive experience in overseas wind-solar-diesel-storage hybrid microgrid projects.
Driven by technology R&D and quality control, we support grid, microgrid, and charging station scenarios
in their low-carbon transition, offering customized, reliable, and safe energy system solutions worldwide.

📞 Phone
+86-13760212825
(WhatsApp / WeChat: COCO)
✉️ Email
info@imaxpwr.com
🏢 Company
Imax Power Technology Co., Ltd.
🛠️ Services
Warranty · After-Sales · Technical Support · Customized Solutions



ImaxPWR · BAC Series Bidirectional Isolated AC/DC Module  ·  Data from official technical specifications

Get In Touch​

We will reply you in 24 hours​

Get In Touch

We will reply you in 24 hours,

We respect your confidentiality and all information are protected.