IMAX PWR ROCK-SOLID SERIES
125 kW / 261 kWh
LIQUID-COOLED ALL-IN-ONE

Imax Power Rock-Solid PS-ESS-125/261
Transformer-Level Energy Storage System

All-in-One Liquid Cooling – Grid-Friendly

Transforming every low-voltage transformer area from a load terminal into a value center.

Imax Power Rock-Solid Series 125kW/261kWh outdoor liquid-cooled cabinet

Rock-Solid Series 125kW / 261kWh outdoor liquid-cooled cabinet (factory photo, logo customizable)

The Transformer-Level Challenge – Why Storage Now Matters

Low-voltage distribution transformer areas are undergoing a source-load reformation: massive distributed PV, EV chargers, and highly fluctuating industrial loads are pushing traditional transformers beyond their design limits. Reverse power flow, over-voltage, three-phase unbalance, and costly transformer upgrades are today’s daily reality.

Imax Power Rock-Solid (PS-ESS) Transformer-Level ESS is engineered precisely for this scenario – an All-in-One liquid-cooled plug-and-play solution designed for 0.4 kV low-voltage transformer areas. With a modular and intelligent architecture, it resolves power quality issues while unlocking new revenue streams for the distribution grid operator or commercial user.

Rock-Solid Series storage cabinet flexible deployment

Rock-Solid Series – flexible outdoor cabinet deployment

Six Core Capabilities – Redefining Transformer-Level Storage

Minimal Integration – Truly Plug-and-Play

Battery PACK, BMS, PCS, EMS, liquid cooling unit, and fire protection – all housed in a single outdoor cabinet. Footprint ≤ 1.3 m². Supports up to 10 cabinets in parallel (261 kWh to 2610 kWh elastic scaling).

Precision Thermal – Liquid Cooling First

Battery-side liquid cooling plus PCS intelligent air cooling; cell temperature difference ≤ 5°C. Rated cycle life of 6,000 cycles (25°C, 0.5P). Whole-cabinet IP55, battery PACK IP67 – dust and condensation proof.

Pack-Level Fire Suppression – Total Safety

PACK-level (temperature / CO) plus compartment-level 5-in-1 detector (temperature / smoke / CO / H2 / VOC). Perfluorohexanone precision injection with water-based fire-extinguishing interface reserved for early detection and suppression.

In-House EMS – Full-Strategy Operation

Peak shaving, demand management, anti-reverse-flow, load tracking, dynamic capacity expansion, and three-phase unbalance compensation. 24/7 cloud remote O&M with proactive fault alerts pushed to your dashboard.

Seamless Grid-Tie / Off-Grid Transition

Dual-mode grid-tie / off-grid operation with switch-over time < 20 ms. In off-grid mode, the unit operates as a voltage source to provide uninterrupted backup power for critical loads (UPS-level capability).

Extreme Environment Ready

Operating temperature -20°C to +50°C. Corrosion resistance class C4-M. Rated altitude ≤ 2,000 m (derated up to 4,000 m). Noise < 70 dB – suitable for commercial and residential areas.

Technical Specifications – PS-ESS-125/261

Parameter Specification
Rated Power / Capacity 125 kW / 261 kWh (0.5P)
Cell Chemistry LiFePO4 (LFP), 3.2 V / 314 Ah – long-cycle life, compliant with GB/T 36276
Module Configuration 1P260S (5 liquid-cooled PACKs in series)
DC Voltage Range 728 ~ 936 V DC
AC Grid Connection 400 V, 3P + N + PE
Peak System Efficiency System ≥ 88% / PCS ≥ 98.5%
Cycle Life 6,000 cycles @ 25°C, 90% DOD, 70% EOL
Fire Suppression PACK-level + compartment-level perfluorohexanone (temp / smoke / CO / H2 / VOC detection)
Cooling Method Liquid cooling on DC side – Air cooling on AC side
Ingress Protection Cabinet IP55 / Battery PACK IP67
Dimensions (W × D × H) 1000 × 1300 × 2400 mm (excluding base)
Weight Approx. 2.8 tonnes
Communication Protocols Modbus TCP / RTU – IEC 104 – MQTT

Customized variants such as 105 kW / 241 kWh are available on request. Multi-cabinet parallel expansion up to 1250 kW / 2610 kWh supported.

Electrical Topology and Operating Modes

AC-Side Parallel Architecture – Battery Cluster Independent Control

Grid 400 V
3P + N + PE
↔
PCS
125 kW Bi-Directional
↔
BMS Master
BCMU – Cluster Level
↔
Battery Cluster
5 PACKs – Independent
BMU x 1
BMU x 2
BMU x 3
BMU x 4
BMU x 5
EMS Local Controller
Modbus TCP / MQTT / IEC 104
↔
Cloud O&M Platform
Remote Monitoring and OTA – 24/7 Alerts
AC-side parallel topology – each cabinet has its own independent PCS and BMS, eliminating inter-cluster circulating currents and enabling incremental scaling from 261 kWh up to 2,610 kWh.

Energy Flow – Typical Transformer-Level Scenario

PV / Utility Grid
Off-peak: Charge Storage
↔
DC Bus
Rock-Solid ESS
125 kW / 261 kWh
Liquid-Cooled All-in-One
↔
AC Bus
Loads / EV
Peak Discharge – Anti-Reverse
Peak Shaving
Dynamic Capacity Boost
Three-Phase Unbalance Compensation
UPS Backup Power
Bidirectional energy flow architecture – perfectly adapted for PV-storage-charger and behind-the-meter scenarios at the transformer level.

Two-Tier BMS Architecture – Sensing Every Cell with Precision

BMU x 1
PACK Level
BMU x 2
PACK Level
BMU x 3
PACK Level
BMU x 4
PACK Level
BMU x 5
PACK Level
↔
Daisy-chain / CAN
BCMU Master
Cluster Level
↔
RS485 / Ethernet
EMS / PCS
System Control
BMU + BCMU two-tier architecture – 28+2 temperature sampling points per PACK, SOC accuracy ≤ 5%, real-time cell-level monitoring.

Protection and Safety – Engineered for 24/7 Reliability

Thermal Runaway Protection

PACK-level perfluorohexanone suppression triggers within seconds upon temperature or CO detection. Compartment-level detectors monitor smoke, H2 and VOC in parallel, ensuring cascading protection at multiple levels.

Electrical Protection

Multi-stage DC/AC over-current, over-voltage, under-voltage, over-frequency, under-frequency and anti-islanding protection, in full compliance with IEC 61000 / GB/T 19064 standards. PCS implements zero-voltage ride-through (ZVRT) capability.

Environmental Resilience

IP55 cabinet ingress protection with corrosion resistance C4-M. IP67 at PACK level. Operating temperature -20°C to +50°C. Designed to sustain continuous operation in coastal, desert, and high-humidity industrial environments.

Proactive Monitoring

Every cell voltage and temperature, every cluster current, every PCS node – continuously monitored. AI-driven anomaly detection pushes proactive alerts to the cloud dashboard 24/7 before issues degrade into faults.

Typical Application Scenarios

Transformer Overload Relief

When transformer loading exceeds 85%, the storage system automatically discharges, effectively extending transformer capacity without expensive hardware upgrades, and deferring capital expenditure.

PV Self-Consumption and Anti-Reverse Flow

Charge batteries during daytime low-tariff hours, discharge during evening peak hours. Zero-power export to upstream grid while maximizing distributed PV self-consumption rate.

Three-Phase Unbalance Compensation

Per-phase power compensation dynamically stabilizes phase voltages, reduces line losses, and extends transformer service life – particularly valuable for asymmetric commercial loads.

Uninterruptible Backup Power (UPS)

Switches to off-grid mode in less than 20 ms upon grid failure, ensuring continuous power to critical loads such as data centers, industrial control rooms, and hospital equipment.

Peak-Valley Arbitrage and Demand Management

Buy low – Sell high – automatically arbitrages along tariff gradients while monitoring demand charges in real time, delivering dual savings under two-part electricity pricing schemes.

Frequently Asked Questions

Q1. Is the Rock-Solid cabinet truly plug-and-play? What on-site work is required?
+

A: Yes. The cabinet ships as a pre-wired, pre-tested, pre-commissioned unit. On site, the customer only needs to provide the foundation / concrete base, AC grid connection (400 V three-phase + N + PE), and an Ethernet / 4G link for EMS cloud monitoring. The unit is typically operational within 4-8 hours after mechanical placement and electrical connection.

Q2. How many cabinets can run in parallel? Is split-phase / multi-area support available?
+

A: Up to 10 cabinets can be paralleled on the AC side for a total of 1,250 kW / 2,610 kWh. Each cabinet has its own independent PCS and BMS, so AC-bus parallelism avoids circulating-current issues and enables flexible, incremental deployment across multiple transformer areas.

Q3. What fire safety certifications does the system hold?
+

A: The Rock-Solid system implements PACK-level perfluorohexanone suppression combined with compartment-level multi-sensor detection (temperature, smoke, CO, H2, VOC). The LFP cells are certified in accordance with IEC 62619 / GB 38031 (UL 9540A on request). A water-based fire-extinguishing interface is reserved at the cabinet level for integration into building-level fire systems.

Q4. Can it operate in areas with high humidity or coastal salt spray?
+

A: Yes. The cabinet is rated IP55 and corrosion class C4-M, specifically designed for coastal and heavy-industrial environments. The battery PACK itself reaches IP67. Surface coatings and structural materials have been selected against salt-spray and sulfur-dioxide corrosion.

Q5. What does O&M look like after installation? Is remote monitoring included?
+

A: Every Rock-Solid cabinet ships with a built-in EMS controller connected to Imax Power’s cloud O&M platform (MQTT / Modbus TCP). Customers receive a dedicated dashboard showing cell-level voltage / temperature, cluster SOC / SOH, PCS power flow, alarms, and analytics – 24/7. Proactive alerts are pushed by email / SMS / WhatsApp. On-site preventive maintenance is typically recommended every 12 months.

Q6. What is the typical return-on-investment period?
+

A: Depending on local tariff structures, PV feed-in conditions, and demand-charge levels, typical IRR ranges from 15% to 25%, with payback usually between 4 and 6 years. Peak-valley arbitrage, demand charge reduction, transformer-upgrade deferral, and potential demand-response or VPP revenue stack together meaningfully. Contact us for a site-specific simulation.

Related Products and Solutions by Imax Power

Sunlight Series – PV-Storage Off-Grid All-in-One

MSP250HCG2 / MSP500HCG2 – Integrated PCS + MPPT + EMS + STS + distribution. 10 ms grid/off-grid switch-over. Ideal for mining camps, islands, oil fields, and emergency construction sites.

Learn more ->

Industrial and Commercial C&I Storage

215 kWh – 1 MWh – 3.44 MWh modular liquid-cooled racks – integrated with Imax PCS for peak shaving, demand management, emergency backup and demand-response aggregation.

Learn more ->

Bidirectional PCS – DC/DC – MPPT Modules

Learn more ->

From a Single Device to a Full Microgrid Core

The Rock-Solid Series is more than a storage cabinet. It is a complete transformer-level energy management solution — integrating PCS, BMS, EMS, liquid cooling, and fire protection in one weatherproof enclosure — truly transforming each low-voltage transformer area from a passive load terminal into an intelligent, revenue-generating energy hub.

Business & Service – Your Global Energy Partner

Phone
WhatsApp / WeChat / Phone
+86-13760212825 (COCO)
Email
Email
info@imaxpwr.com
Website
Website
imax-pwr.com

Get Custom Proposal ->

Company entity: Imax Power Technology Co., Ltd. – National high-tech enterprise specialized in new-energy power conversion and energy storage systems. Ships worldwide.
Warranty Promise

Core components (PCS, EMS, BMS) warranted for 5 years. Optional extended warranty up to 8 or 10 years available on project request.

Technical Support

End-to-end from requirements to delivery – on-site survey, system design, EMS strategy optimization, owner/operator training, optional turn-key delivery.

Customized Solutions

Beyond the standard 125 kW / 261 kWh model we engineer project-level variants with custom power ratings, voltage ranges and communication protocols.